Product Information:
Manufacturer: Microtrac
Model: Wave
Year: 2019
Serial #: W3992
Product ID: 230401

Additional details:
Condition: Very Good
Weight: lbs
Dimensions: in. X in. X in. (width X height X depth)
System: Particle Analyzer
Location: Western, USA

Detailed Description:

Introducing Nanotrac Wave - Manufacturer details provided below

Measures the particle size and distribution of dispersions 0.8 to 6,500 nanometers

Microtrac has been a pioneer in particle sizing technology for over 30 years! The Nanotrac Wave is the latest generation of sub-micron Particle Size and Zeta Potential analyzers from Microtrac! The enhanced design on the Nanotrac Wave features faster measurements, smaller particle size capability (to 0.8 nm), higher precision, higher accuracy and advanced software capabilities in a small, robust dynamic light scattering instrument with no moving components. Nanotrac Wave complies with the ISO 13321 standard for Dynamic Light Scattering.

Features

Technology    Dynamic Light Scattering incorporating the patented Controlled Reference Method for
advanced power spectrum analysis of Doppler shifts under Brownian Motion.
Range    Measurement capability from 0.8 to 6500 nanometers. Zeta Potential from -125 to +125MV
Sample Size    Typically less than 3ml in standard cell, or 0.2ml with small cell option.
Rapid Analysis    15 to 30 second analysis times in most cases.
Analysis Simplicity    No “A Priori” or advance knowledge of the sample is required. Nanotrac will accurately report monomodal, multimodal, broad and narrow distributions without the need to select
special calculation algorithms.


Accuracy Measures using Mie scattering calculations for spherical particles and proprietary Mie
calculations for non-spherical particles. This feature is unique to Microtrac.
Repeatability    Better than 1% from instrument to instrument for 100nm polystyrene.
Traceability    Particle Size measurements traceable to NIST standards.
Sample Cell Modules    Nano, Zeta, Micro insert for Nano Cell, Flow thru cell with or withouit cap.
Concentration    Capable to measure up to 40% by solids in some cases. This feature reduces the need to
dilute samples which may affect particle size or colloid stability. Low concentration
measurements can be as low as 0.1ppm for 200nm polystyrene.
Temperature Control    Precise temperature control using a Peltier control device.
Versatility    Nanotrac Wave probe can be external for use in Dip-N-Run or in-line applications. Nanotrac
Wave is also compatible with the Zetrator titration device.
Security/Validation    Nanotrac Wave FLEX software is compatible with FDA 21 CFR Part 11 protocols. Full
IQ/OQ/PQ validation documentation is available for Nanotrac Wave.

Specifications
     
Particle Size 0.08 to 6500 nanometers (displayed in nanometers, microns or angstroms)
Zeta Potential    -125 to +125 mV, Mobility -10 to +10 microseconds/volt/cm, size range 10nm to 20 microns
Molecular Weight    1kDa to 20 MDa, Hydrodynamic, Debye Plot with 2nd Virial co-efficient calculation
Sample Volume    Size only - 50 ul to 500 ul, with micro insert min 10 to 20 ul. Zeta 0.7 to 3 ml.
Measurement Angle    180 Degrees    
Repeatability    1% or better for 100nm Polystyrene
Concentraion Limits    From ppb to 40% by volume in certain conditions.
Laser    Laser Diode, 780 nm , 3mW Nominal, Class IIIB, no alignment required.
Temperature Control    5 to 90 Degrees Centigrade +/- 0.2 Degrees using Peltier Device
Sample Cell Modules    Nano, Zeta, Micro insert for Nano Cell, Flow thru cell with or withouit cap.
Chemical Compatibility    Aqueous, polar and non polar solvents, organic solvents. Surfaces-Stainless steel, sapphire and Teflon
pH Range    2 to 12 pH
Conductivity Range    1 to 200 mS/cm
Environmental    Operating Temperature   10 to 50 Degrees C
Humidity                up to 90% non condensing
Dimensions    15L x 14W x 13H inches (38.1 x 35.5 x 33 cms)
Weight    30 Lbs, approx 15 Kg
Electrical    90 to 240 VAC, 47 to 63 HZ, 5 Amps